Caution
This is the documentation for the current development branch of the CometVisu. It is possible that some of the described features are not yet available in the current release.
Also there might be lots of errors in this documentation as some parts of the content have been translated by an online translation service.
Temperature from 1wire (local 1wire interface with owfs)
If you use 1wire you can use this script to read the values directly from a 1wire sensor and fill it into an RRD database. Here the 1wire sensor has the ID 28.AB8BCB040000, this must be adjusted! This script works like this if it is stored (and executable) under /var/www/rrd/1wire_temp_outside.
#!/bin/bash
#
cd /var/www/rrd
# create database if not exists
[ -f 1wire_temp_outside.rrd ] || {
/usr/bin/rrdtool create 1wire_temp_outside.rrd --step 300 \
DS:temp:GAUGE:1200:U:U \
RRA:AVERAGE:0.5:1:3200 \
RRA:AVERAGE:0.5:6:3200 \
RRA:AVERAGE:0.5:36:3200 \
RRA:AVERAGE:0.5:144:3200 \
RRA:AVERAGE:0.5:1008:3200 \
RRA:AVERAGE:0.5:4320:3200 \
RRA:AVERAGE:0.5:52560:3200 \
RRA:AVERAGE:0.5:525600:3200
}
# read the temperature (degrees celsius)
TEMPERATURE=`owget /uncached/28.AB8BCB040000/temperature`
# remove leading character
TEMPERATURE=`echo $TEMPERATURE | cut -c 1-`
/usr/bin/rrdtool update 1wire_temp_outside.rrd N:$TEMPERATURE
The following line must be added in /etc/crontab to call the script every 5 minutes:
*/5 * * * * root /var/www/rrd/1wire_temp_outside